R – Product Series
(products below: R 281 | R 281(2x) | R 451 | R 451(2x))
Temperature Range: –50°C...+600°C
Platinum temperature sensors in round housing
Advantages: Facilitates mounting
| Specification: | DIN EN 60751 |
| Temperature range: | -50°C to +600°C |
| Temperature Coefficient: | TCR = 3850 ppm/K |
| Tolerance Classes: | F 0.1 (Class Y) -50°C to +150°C F 0.15 (Class A) -50°C to +300°C F 0.3 (Class B) -50°C to +600°C F 0.6 (Class C) -50°C to +600°C 1/5 F 0.3 (Class K) on request 1/10 F 0.3 (Class K) on request |
| Leads: | Platinum-coated nickel wire (Ø = 0.2 mm) Recommended connection technology: Soldering, Welding, Crimping |
| Lead Lengths: | 7 mm |
| Long-term stability: | Max. Drift = Less than 0.03% after 1000h at max. operating temperature |
| Note: | Only usable in dry environment |
R 281
| Dimensions, LxØ: | 13.0 x 2.8 mm | |
| Nominal Resistance at 0°C (ohm): |
100/500/1000 | |
| Self Heating (mK): | Water (v= 0 m/s) | ∆Tw = 1.7 at 0°C |
| Air (v= 0 m/s) | ∆Ta = 18 at 0°C | |
| Response Time (s): | Water (v= 0.4 m/s) | T0.5 = 2.5 |
| T0.63 = 4.5 | ||
| T0.9 = 8 | ||
| Air (v= 1 m/s) | T0.5 = 10 | |
| T0.63 = 15 | ||
| T0.9 = 28 | ||
| Measuring Current (mA): | 100 Ω: 1 | |
| 500 Ω: 0.5 | ||
| 1000 Ω: 0.3 |
R 281(2x)
| Dimensions, LxØ: | 13.0 x 2.8 mm | |
| Nominal Resistance at 0°C (ohm): |
100/500/1000 | |
| Self Heating (mK): | Water (v= 0 m/s) | ∆Tw = 2.2 at 0°C |
| Air (v= 0 m/s) | ∆Ta = 25 at 0°C | |
| Response Time (s): | Water (v= 0.4 m/s) | T0.5 = 2 |
| T0.63 = 2.5 | ||
| T0.9 = 5.5 | ||
| Air (v= 1 m/s) | T0.5 = 10 | |
| T0.63 = 12 | ||
| T0.9 = 22 | ||
| Measuring Current (mA): | 100 Ω: 1 | |
| 500 Ω: 0.5 | ||
| 1000 Ω: 0.3 | ||
| Note: | 2 sensors in 1 ceramic tube | |
R 451
| Dimensions, LxØ: | 13.0 x 4.5 mm | |
| Nominal Resistance at 0°C (ohm): |
100/500/1000 | |
| Self Heating (mK): | Water (v= 0 m/s) | ∆Tw = 1.2 at 0°C |
| Air (v= 0 m/s) | ∆Ta = 13 at 0°C | |
| Response Time (s): | Water (v= 0.4 m/s) | T0.5 = 8 |
| T0.63 = 10 | ||
| T0.9 = 22 | ||
| Air (v= 1 m/s) | T0.5 = 12 | |
| T0.63 = 22 | ||
| T0.9 = 40 | ||
| Measuring Current (mA): | 100 Ω: 1 | |
| 500 Ω: 0.5 | ||
| 1000 Ω: 0.3 |
R 451(2x)
| Dimensions, LxØ: | 13.0 x 4.5 mm | |
| Nominal Resistance at 0°C (ohm): |
100/500/1000 | |
| Self Heating (mK): | Water (v= 0 m/s) | ∆Tw = 1.2 at 0°C |
| Air (v= 0 m/s) | ∆Ta = 13 at 0°C | |
| Response Time (s): | Water (v= 0.4 m/s) | T0.5 = 8 |
| T0.63 = 10 | ||
| T0.9 = 22 | ||
| Air (v= 1 m/s) | T0.5 = 12 | |
| T0.63 = 22 | ||
| T0.9 = 40 | ||
| Measuring Current (mA): | 100 Ω: 1 | |
| 500 Ω: 0.5 | ||
| 1000 Ω: 0.3 | ||
| Note: | 2 sensors in 1 ceramic tube | |
| Order Example: | ||||||
| P | 1K0. | 281. | 6 | W. | B. | R |
| 1 | 2 | 3 | 4 | 5 | 6 | 7 |
| 1. Material Identification = Platinum temperature sensor 2. Resistance Value in ohm = 1000Ω / 0°C 3. Chip Dimension = 13.0 x 2.8 mm 4. Temperature Range = -50°C to +600°C 5. Extension = Wire Connections 6. Tolerance Class = DIN EN 60751 F 0.3 (former Class B) 7. Special = Round housing |
||||||